








- Zero-Ozone UV Light: Rated at 36 W for stronger UV disinfection than standard 6-25W lamps; operates atββ instant and maximum germicidal efficiencyββ due to 253.7nm wavelength UV-C light; a slight odor during first use is normal
- Safe Performance: ETL listed for safe use; CARB certified and meets California ozone emissions limit; maintains ozone levels below 0.05 ppm (equivalent to 0 ozone); safe for use when used as intended
- Hassle-Free Installation: Includes an installation template for easy placement on duct exteriors; simply drill, insert the lamp, and secure the ballast with screws; requires at least 16 inches of space and a nearby socket for setup and use
Versatile HVAC Use: Helps reduce contaminants in circulated air and internal components of AC systems; suitable for HVAC systems in schools, hospitals, hotels, offices, and more - Reliable Construction: Built with a 2G11 4-pin ceramic base and quartz glass for clear UV light transmission; enhances longevity for continuous use
- Easy Status-Check: Built-in green light indicates active operation; light turns off to indicate bulb replacement or error, simplifying troubleshooting and maintenance
- Use only with TURBRO UV lamps; avoid direct exposure to UV light to protect people, pets, and plants; do not handle UV bulbs with bare hands.
How to Choose?

Standard Version (UV36P)
The UV36P Standard delivers powerful 36W UV sterilization with a direct 120V plug-in design.
- Perfect for users who want continuous air purification with no extra setup
- Most budget-friendly option with easy maintenance

With Smart Socket (UV36PW)
Includes a smart plug for remote operation at home or while youβre away; features schedule, countdown, random, and circulate modes; ONLY compatible with 2.4GHz frequency WiFi
- Ideal for users who want flexible scheduling, remote control, or smart-home integration.

With Air Sensor (UV36PA)
Designed with an energy-saving airflow sensor for customized UV protection.
Switch between HOLD mode for continuous disinfection or AIRFLOW mode to activate only when air is detected.
- Best for those seeking hands-free automation and lower power consumption without sacrificing effectiveness.
Package Contents

Standard Version (UV36P)
Ballast x 1
15.2" UV Lamp x 1
Installation Template x 1
2-1/4" Drill x 1 Set
Mounting Screws x 4
Seal Strips x 4

With Smart Socket (UV36PW)
Ballast x 1
15.2" UV Lamp x 2
Installation Template x 1
2-1/4" Drill x 1 Set
Mounting Screws x 4
Seal Strips x 4
UV Light User Manual
Smart Plug
Plug Instructions

With Air Sensor (UV36PA)
Ballast x 1
15.2" UV Lamp x 1
Installation Template x 1
2-1/4" Drill x 1 Set
Mounting Screws x 4
Seal Strips x 4
FAQ
ββQ: Does this light produce ozone?ββ
ββA:ββ No, it does ozone-free sterilization.
ββQ: What is the wavelength of the light?ββ
ββA:ββ It emits 253.7 nm UV-C light, which is optimal for disinfection and sterilization.
ββQ: Can I look at the light while itβs operating?ββ
ββA:ββ No. Never stare at or expose any living organisms to the operating UV light, as it may cause harm to the eyes or skin.
Q: What type of bulb does it use? Can it be used in units from other brands?ββ
ββA:ββ The bulb is made of quartz glass with a ceramic base, specifically a 2G11 4-pin type. It can be used in compatible fixtures from other brands that support the same base type.
ββQ: Is this light compatible with my existing HVAC system?ββ
ββA:ββ The bulb itself is 15.2 inches long (including the base, excluding pins). Model UV36D requires at least 17 inches of space inside the duct. For other models, at least 16 inches of space is required. Additionally, installation involves drilling holes into the duct surface. Please confirm that your duct allows for such modifications.
ββQ: Is it hardwired or plug-in?ββ
ββA:ββ Model UV36D requires hardwiring (100β240 V). Other models come with a plug and need to be connected to a 120V power outlet.
Q: How often do I need to do maintenance?ββ
ββA:ββ We recommend inspecting and cleaning the UV lamp at least every 3 months. The frequency may vary depending on your home environment, usage patterns, and replacement schedule. Before maintenance, always disconnect power and allow the lamp to cool for at least 15 minutes. Wear disposable, non-absorbent protective gloves during handling to prevent injury in case of glass breakage.
ββQ: How often should I replace the lamp? What type should be used?ββ
ββA:ββ For optimal performance, we recommend replacing the lamp every 6 months. Use only TURBRO replacement lamps. A 2-piece replacement set is available for separate purchase if needed. When replacing, wear disposable liquid-resistant gloves to avoid injury from potential glass breakage.
ββQ: I notice a distinct smell when using the lamp for the first time. Is this normal?ββ
ββA:ββ Yes, that is normal. During initial operation, the high-output UV light works to eliminate microorganisms in the duct system, which may produce a temporary odor. We recommend running the lamp continuously for at least 24 hours when first used.
ββQ: What Wi-Fi frequency is required for the smart plug?ββ
ββA:ββ It is only compatible with 2.4 GHz Wi-Fi networks.
Q: What certifications does it have? Can it be used in California?ββ
ββA:ββ The five modelsβUV36D, UV36P, UV72P, UV36PW, and UV72PWβare ETL listed and CARB certified, and are approved for sale and use in California.
Specification
Model |
UV36D |
UV36P |
UV36PW |
UV36PA |
UV72P |
UV72PW |
UV72PA |
Rated Power |
36 W |
36 W |
36 W |
36 W |
72 W |
72 W |
72 W |
Recommended Air System Capacity |
<36,000 BTU |
<36,000 BTU |
<36,000 BTU |
<36000 BTU |
36,000 BTU and above |
36,000 BTU and above |
36000 BTU and above |
Min. Depth Required |
17.0 in |
16.0 in |
16.0 in |
16.0 in |
16.0 in |
16.0 in |
16.0 in |
Package Weight |
2.5 lb |
3.5-3.6 lb |
3.5-3.6 lb |
3.6 lb |
4.7-4.9 lb |
4.7-4.9 lb |
4.9 lb |
Installation Method |
Magnetic |
Mounting |
Mounting |
Mounting |
Mounting |
Mounting |
Mounting |
Power Supply |
WiringΒ (100-240 V) |
Direct Plug-InΒ (120 V) |
Direct Plug-InΒ (120 V) |
Direct Plug-In Β (120 V) |
Direct Plug-In Β (120 V) |
Direct Plug-In Β (120 V) |
Direct Plug-In Β (120 V) |
Number of Lamps |
1 |
1 |
1 |
1 |
2 |
2 |
2 |
Installation Template |
β |
β |
β |
β |
β |
β |
β |
Air Sensor |
β |
β |
β |
β |
β |
β |
β |
With Smart Socket |
β |
β |
β |
β |
β |
β |
β |